Designing of draining trenches

Our technical staff is able to predict you the expected drawdown of the groundwater, using our drainage systems, our software for designing are:

Drainfilepro (based on Hooughodt theory)

PARAMETERS INPUT  UNIT
l (drain length) 60 m
q (rainfall) 10 mm/day
depth of trench 4,0 m
h (height of water) 0,6 m
K1(permeability over the drains) 6E-06 m/s
K2 (permeabilità under drains) 1E-09 m/s
D (distance drain-clay) 0,15 m
r (drain radius) 0,1 m
Rh (horizontal res.ce) 6,74 ad
Rrad (radial res.ce) 0,02 ad
d (layer thickness) 0,16 m

see a complete project calculation made with DRAINFILEPRO

 

If you need to design with our products, fill the project check request (it is free),send it to info@idroter.com, in a short time you can receive:

1) a complete check of groundwater balance conditions using our products for your project

2) the expected flow-rate of our products under projects conditions

3) the expected flow-rate of our products for particular rainfall (20 times higher than usual)

 

 

 

 

f.e.m. analysis example




Initial conditions


  Balance conditions using draining panels
 

Ask for f.e.m. design assistence