Idroter di Martinelli Francesco

      Patented drainage systems for trenches,foundations,walls

Designing (reserved area register)

Designing of draining trenches

Our freeware allows to calculate the draindistance and expected drawdown of the groundwater, using our draining panels DRENOTER, the software is only for registered members:

Drainfilepro (based on Hooughodt theory)

PARAMETERS INPUT  UNIT
l (drain length) 60 m
q (rainfall) 10 mm/day
depth of trench 4,0 m
h (height of water) 0,6 m
K1(permeability over the drains) 6E-06 m/s
K2 (permeabilità under drains) 1E-09 m/s
D (distance drain-clay) 0,15 m
r (drain radius) 0,1 m
Rh (horizontal res.ce) 6,74 ad
Rrad (radial res.ce) 0,02 ad
d (layer thickness) 0,16 m

Before downloading you must belong to datasheet of registered members (files are protected with password); please register

download DRAINFILEPRO

If you need to design with our products, fill the project check request (it is free),send it to info@idroter.com, in a short time you can receive:

1) a complete check of groundwater balance conditions using our products for your project

2) the expected flow-rate of our products under projects conditions

3) the expected flow-rate of our products for particular rainfall (20 times higher than usual)